Detail 0812-8222-8891 Multimeter Digital PS-VC9805 Digital Multimeter Inductance Capacitance Resistance Thermometer Ohm° C/ ° F, Harga Jual VC-9805 Digital Multimeter Murah Di Jakarta Indonesia.
VC9805 Digital Multimeter Inductance Capacitance Resistance Thermometer Ohm° C/ ° F , VC-9805 Capacitance Meter
Description :
This Professional Digital Multimeter ( VC9805A) is made by VICTOR brand. It is a high performance, stable and accurate instrument with large backlight LCD display ( height 42mm) to measure DC and AC voltage, DC and AC current, Resistance, Capacitance, Inductance, Temperature, Frequency, Transistor, Diode, Triode and Continuity Test.
The designed parameter include: unit indication, data hold ( HOLD) , auto off and buzzer sounds. The instrument takes dual-integral A/ D converter as a key point, this multimeter is most suitable for use on production lines or lab, R & D, maintenance and repairing work.
Features
Dual-slope DC/ AC converter CMOS technology for auto-zero, polarity selection and over-range indication.
Full overload protection
New type holster, streamline design
3 ½ digit Large LCD Display
Metallic screen board with stronger antimagnetic and anti-interferential function.
Full function protection, anti-high voltage circuit design.
Low battery display indication
General Specifications
Display: 3 ½ digit Large LCD with a max readings of 1999.
Auto Polarity indication
Measuring method: Dual-slope A/ D Transfer
Sampling Rate: approx. 3 Times / Second
Over range indication: MSD displays " 1" / " OL" or " -1" / " -OL"
Safety Standards: CE; IEC1010
Operating Temperature: 0 ~ 40 ° C ( 32 ~ 104 ° F)
Operating Humidity: below 80% RH
Storage Temperature: -10 ~ 50 ° C ( 14 ~ 122 ° F)
Storage Humidity: below 80% RH
Low battery display auto turn off ( after turn on 15 minutes)
Power: 1 x 9 V PP3 battery ( not included)
Dimensions: 190 ( H) x 93.5 ( W) x 37 ( D) mm ( 7.48' x 3.68' x 1.46' inch)
Weight: approx. 448g ( 15.8 oz)
Electrical Specifications
Accuracy is ± ( percentage of reading + number of digit) at ( 23± 5) ° C, < 75% Relative humidity.
DC Voltage
Range
Accuracy
Resolution
200 mV
± ( 0.5% + 3d)
100 ¼ V
2 V
1 mV
20 V
10 mV
200 V
100 mV
1000 V
± ( 0.8% + 10d)
1 V
Input impedance: 10 M©
Overload protection:
Range 200mV: DC 250V or AC peak value
Other ranges: 1000 V DC or AC peak value
AC Voltage
Range
Accuracy
Resolution
200 mV
± ( 0.8% + 5d)
100 ¼ V
2 V
1 mV
20 V
10 mV
200 V
100 mV
750 V
± ( 1.2% + 5d)
1 V
Input impedance: 400 mV range: more than 40 M© ; other range: 10 M©
Overload protection: Range 200 mV: DC 250 V or AC peak value
Other ranges: DC 1000 V or AC peak value
Frequency response: Range less than 200 V: 40-400 Hz ; Range 750 V: 40-100 Hz
Indication: RMS of sine wave ( mean value response)
DC Current
Range
Accuracy
Resolution
2 mA
± ( 0.8% + 10d)
1 ¼ A
20 mA
10 ¼ A
200 mA
± ( 1.2% + 8d)
100 ¼ A
20 A
± ( 2.0% + 5d)
10 mA
Max measuring voltage drop: 200 mV
Max input current: 20A ( within 10 seconds)
Overload protection: 0.2A / 250V restorable fuse, range 20A infused.
AC Current
Range
Accuracy
Resolution
2 mA
± ( 1.0% + 15d)
1 ¼ A
20 mA
10 ¼ A
200 mA
± ( 2.0% + 5d)
100 ¼ A
20 A
± ( 3.0% + 10d)
10 mA
Max measuring voltage drop: 200 mV
Max input current: 20A ( within 10 seconds)
Overload protection: 0.2A / 250V restorable fuse, range 20A infused.
Frequency response: 40-100 Hz
Indication: RMS of sine wave ( mean value response)
Resistance ( © )
Range
Accuracy
Resolution
200 ©
± ( 0.8% + 5d)
0.1 ©
2k ©
± ( 0.8% + 3d)
1 ©
20k ©
10 ©
200k ©
100 ©
2M ©
1k ©
20M ©
± ( 1.0% + 15d)
10k ©
Open voltage: less than 3V
Overload protection: 250V DC/ AC Peak Value
Note:
A. At range 200 © , short-circuit the test leads to measure the resistance of the wire, then subtracts it from the real measurement.
B. At range 200 M© , when the test leads short circuit, LCD displays 1.0 M© . In the same way, the reading is 10 M© while the test leads short at range 2000 M© . It’ s normal and does not affect the accuracy. Please deduct the value from the real measurement.
C. The reading should be displayed slowly when the measurement is more than 1 M© . Please wait until stable.
Capacitance
Range
Accuracy
Resolution
20 nF
± ( 2.5% + 20d)
10 pF
200 nF
100 pF
2 ¼ F
1 nF
20 ¼ F
10 nF
200 ¼ F
± ( 5.0% + 10d)
100 nF
Overload protection: 36V DC/ AC Peak Value
Inductance ( L)
Range
Accuracy
Resolution
2 mH
± ( 2.5% + 30d)
1 ¼ H
20 mH
10 ¼ H
200 mH
100 ¼ H
2 H
1 mH
20 H
10 mH
Overload protection: 36V DC/ AC Peak Value
Temperature
Range
Accuracy
Resolution
-20 - 1000 ° C
< 400 ° C, ± ( 1.0% + 5d)
e 400 ° C, ± ( 1.5% + 15d)
1 ° C
0 - 1832 ° F
< 750 ° F ± ( 0.75% + 5d)
e 750 ° F ± ( 1.5% + 15d)
1 ° F
Thermocouple: K Type ( Banana shape plug)
Frequency
Range
Accuracy
Resolution
200 kHz
± ( 3.0% + 18d)
100 Hz
Input Sensitivity: 1.0V RMS
Overload protection: 250V DC/ AC Peak Value ( within 10 seconds)
Diode and Continuity Testing
Range
Description
Condition
Diode
Forward Voltage drop of Diode
Forward DC Current is approx. 1 mA. Backward voltage is approx. 3 V
Buzzer
Buzzer makes a long sounds while resistance is less than ( 70 ± 20) Ohms
Open Circuit Voltage is approx. 3 V
Overload Protection: 250 V DC/ AC peak value
Warning: Do not input Voltage at the range for safety
Transistor hFE Data Test
Range
Display Range
Test Condition
hFE NPN or PNP
0 ~ 1000
Basic current is approx. 10 ¼ A, Vce is about 3V
One Set Included:
1 x Multifunction Digital Multimeter
Test Leads
1 x K-Type Thermocouple
1 x Instruction Manual
Standard Factory Package
Tampilkan Lebih Banyak